An uncertainty analysis of the PVT gauging method
责任编辑:hylng    浏览:5202次    时间: 2013-06-03 15:13:55      

免职声明:本网站为公益性网站,部分信息来自网络,如果涉及贵网站的知识产权,请及时反馈,我们承诺第一时间删除!

This website is a public welfare website, part of the information from the Internet, if it involves the intellectual property rights of your website, please timely feedback, we promise to delete the first time.

电话Tel: 19550540085: QQ号: 929496072 or 邮箱Email: Lng@vip.qq.com

摘要:The PVT (pressure, volume, temperature) method of liquid quantity gauging in low-gravity is based on gas law calculationsassuming conservation of pressurant gas within the propellant tank and the pressurant supply bottle. There is interest in appl..

分享到:

The PVT (pressure, volume, temperature) method of liquid quantity gauging in low-gravity is based on gas law calculations
assuming conservation of pressurant gas within the propellant tank and the pressurant supply bottle. There is interest in applying
this method to cryogenic propellant tanks since the method requires minimal additional hardware or instrumentation. To use PVT
with cryogenic fluids, a non-condensable pressurant gas (helium) is required. With cryogens, there will be a significant amount of
propellant vapor mixed with the pressurant gas in the tank ullage. This condition, along with the high sensitivity of propellant vapor
pressure to temperature, makes the PVT method susceptible to substantially greater measurement uncertainty than is the case with
less volatile propellants. A conventional uncertainty analysis is applied to example cases of liquid hydrogen and liquid oxygen tanks.
It appears that the PVT method may be feasible for liquid oxygen. Acceptable accuracy will be more difficult to obtain with liquid
hydrogen.

】【打印繁体】【投稿】 【收藏】 【推荐】 【举报】 【评论】 【关闭】【返回顶部